| Modello | VN-M150HE | VN-M250HE | VN-M350HE | VN-M500HE | VN-M650HE | VN-M800HE | VN-M1000HE | VN-M1500HE | VN-M2000HE | |||
| Portata d’aria | (eh/h/l) | m3/h | 150/150/110 | 250/250/155 | 350/350/210 | 500/500/390 | 650/650/520 | 800/800/700 | 1000/1000/755 | 1500/1500/1200 | 2000/2000/1400 | |
| Efficienza di scambio termico | (eh/h/l) | % | 81,5/81,5/83 | 78/78/81,5 | 74,5/74,5/79,5 | 76,5/76,5/78 | 75/75/76,5 | 76,5/76,5/77,5 | 73,5/73,5/77 | 76,5/76,5/79 | 73,5/73,5/77,5 | |
| Efficienza di scambio entalpico (Riscaldamento) | (eh/h/l) | % | 74,5/74,5/76 | 70/70/74 | 65/65/71,5 | 72/72/73,5 | 69,5/69,5/71,5 | 71/71/71,5 | 68,5/68,5/71,5 | 71/71/73,5 | 68,5/68,5/72 | |
| Efficienza di scambio entalpico (Raffrescamento) | (eh/h/l) | % | 69,5/69,5/71 | 65/65/69 | 60,5/60,5/67 | 64,5/64,5/66,5 | 61,5/61,5/64 | 64/64/65,5 | 60,5/60,5/64,5 | 64/64/67 | 60,5/60,5/65,5 | |
| Livello di pressione sonora1 2 | eh | dB(A) | 26-28 | 29,5-30 | 34-35 | 32,5-34 | 34-36 | 37-38,5 | 39,5-40,5 | 38-39 | 42,5-43,5 | |
| Livello di pressione sonora1 2 | h | dB(A) | 24-25,5 | 25-27 | 30-32 | 29,5-31 | 33-34 | 35,5-37 | 38,5-40 | 36,5-37,5 | 41,5-43 | |
| Livello di pressione sonora1 2 | l | dB(A) | 20-22 | 21-22 | 27-29 | 26-29 | 31-32,5 | 33,5-35 | 34-35,5 | 36-37,5 | 37-38,5 | |
| Potenza assorbita2 | eh | W | 68-78 | 123-138 | 165-182 | 214-238 | 262-290 | 360-383 | 532-569 | 751-786 | 1084-1154 | |
| Potenza assorbita2 | h | W | 59-67 | 99-111 | 135-145 | 176-192 | 240-258 | 339-353 | 494-538 | 708-784 | 1032-1080 | |
| Potenza assorbita2 | l | W | 42-47 | 52-59 | 82-88 | 128-142 | 178-191 | 286-300 | 353-370 | 570-607 | 702-742 | |
| Pressione statica esterna2 | eh | Pa | 82-102 | 80-98 | 114-125 | 134-150 | 91-107 | 142-158 | 130-150 | 135-156 | 124-143 | |
| Pressione statica esterna2 | h | Pa | 52-78 | 34-65 | 56-83 | 69-99 | 58-82 | 102-132 | 97-122 | 103-129 | 92-116 | |
| Pressione statica esterna2 | l | Pa | 47-64 | 28-40 | 65-94 | 62-92 | 61-96 | 76-112 | 84-127 | 112-142 | 110-143 | |
| Dimensioni (A x L x P) | mm | 290 x 900 x 900 | 290 x 900 x 900 | 290 x 900 x 900 | 350 x 1140 x 1140 | 350 x 1140 x 1140 | 400 x 1189 x 1189 | 400 x 1189 x 1189 | 810 x 1189 x 1189 | 810 x 1189 x 1189 | ||
| Peso | kg | 36.00 | 36.00 | 38.00 | 53.00 | 53.00 | 70.00 | 70.00 | 143.00 | 143.00 | ||
| Diametro condotti | mm | 100.00 | 150.00 | 150.00 | 200.00 | 200.00 | 250.00 | 250.00 | 250.00 | 250.00 | ||
| Alimentazione | V-ph-Hz | 220-240 - 1 - 50 | ||||||||||
| Campo temperatura di funzionamento - aria estratta | -10°C ÷ +40°C, 80% UR o inferiore | |||||||||||
| Campo temperatura di funzionamento - aria esterna | -15°C ÷ +43°C | |||||||||||
| Temperatura locale | +5°C ÷ +40°C, 80% UR o inferiore | |||||||||||
| 1) Livello di pressione sonora misurata ad 1,5 m dal fondo al centro dell’unità. | _ | |||||||||||
| 2) Livello di pressione sonora, potenza assorbita e valori di pressione statica esterna a 220 - 240 V | _ | |||||||||||
| eh/hl/l = super alta/alta/bassa | _ | |||||||||||
| The specification may be subject to change without notice for purpose of improvement. | ||||||||||||