| UNITA' INTERNA | RAV-SM564UTP-E | RAV-SM804UTP-E | RAV-SM1104UPT-E | RAV-SM1104UTP-E | RAV-SM1404UTP-E | RAV-SM1404UTP-E | RAV-SM1604UTP-E | ||
| UNITA' ESTERNA | RAV-SP564ATP-E | RAV-SP804ATP-E | RAV-SP1104AT-E | RAV-SP1104AT8-E | RAV-SP1404AT-E | RAV-SP1404AT8-E | RAV-SP1604AT8-E | ||
| Capacità nominale | kW | 5,3 | 7,1 | 10,0 | 10,0 | 12.50 | 12,5 | 14,0 | |
| Capacità min. – max. | kW | 1,2 - 5,6 | 1,9 - 8,0 | 2,6 - 12,0 | 2,6 - 12,0 | 2,6 - 14,0 | 2,6 - 14,0 | 2,6 - 16,0 | |
| Potenza assorbita (min. – nominale – max.) | kW | 0,20 - 1,47 - 1,95 | 0,30 - 1,86 - 2,52 | 0,64 - 2,21 - 3,60 | 0,66 -2,37- 3,60 | 0,64 - 3,16 - 4,40 | 0,66 - 3,46 - 4,40 | 0,66 - 4,49 - 5,70 | |
| Pdesignc | kW | 5.30 | 7.10 | 10.00 | 10.00 | ||||
| SEER | W/W | 6.20 | 6.40 | 6.60 | 6.60 | - | - | - | |
| Classe di efficienza energetica | A++ | A++ | A++ | A++ | - | - | - | ||
| Consumo energetico stagionale | kWh | 301.00 | 389.00 | 530.00 | 532.00 | - | - | - | |
| EER | W/W | - | - | - | 4.22 | 3,96 | 3,61 | 3,12 | |
| Capacità nominale | kW | 5,6 | 8,0 | 11.20 | 11.20 | 14,0 | 14,0 | 16,0 | |
| Capacità min. – max. | kW | 0,9 - 8,1 | 1,3 - 11,3 | 2,4 - 13,0 | 2,4 - 15,6 | 2,4 - 16,5 | 2,4 - 18,0 | 2,4 - 19,0 | |
| Potenza assorbita (min. – nominale – max.) | kW | 0,15 - 1,21 - 2,40 | 0,25 - 1,91 - 3,52 | 0,52 - 2,34- 4,20 | 0,53 -2,42 - 4,30 | 0,52 - 3,21 - 4,50 | 0,53 -3,42 - 5,50 | 0,53 -4,30 - 6,51 | |
| Pdesignh | kW | 5.40 | 7.60 | 11.60 | 11.60 | ||||
| SCOP | W/W | 4.60 | 4.20 | 4.30 | 4.30 | - | - | - | |
| Classe di efficienza energetica | H | A+ | A+ | A+ | A+ | - | - | - | |
| Consumo energetico stagionale | kWh | 1649.00 | 2542.00 | 3795.00 | 3795.00 | - | - | - | |
| COP | W/W | - | - | - | 4.63 | 4,36 | 4,09 | 3,72 | |
| UNITA' INTERNA | RAV-SM564UT-E | RAV-SM804UT-E | RAV-SM1104UT-E | RAV-SM1104UT-E | RAV-SM1404UT-E | RAV-SM1404UT-E | RAV-SM1604UT-E | ||
| UNITA' INTERNA | RAV-SM564UTP-E | RAV-SM804UTP-E | RAV-SM1104UTP-E | RAV-SM1104UTP-E | RAV-SM1404UTP-E | RAV-SM1404UTP-E | RAV-SM1604UTP-E | ||
| Portata Aria (a-m-b) | m³/min | 17,5-14,5-13,0 | 20,5-16,0-13,5 | 33,5-24,0-19,5 | 33,5-24,0-19,5 | 35,0-24,0-20,5 | 35,0-24,0-20,5 | 35,5-25,0-21,0 | |
| Livello di pressione sonora (a-m-b) | dB(A) | 32-29-28 | 35-31-28 | 43-38-33 | 43-38-33 | 44-38-34 | 44-38-34 | 45-40-36 | |
| Livello di potenza sonora (a-m-b) | dB(A) | 47-44-43 | 50-46-43 | 58-53-48 | 58-53-48 | 59-53-49 | 59-53-49 | 60-55-51 | |
| Pompa scarico condensa | inclusa | inclusa | inclusa | inclusa | inclusa | inclusa | inclusa | ||
| Prevalenza pompa | mm | 660.00 | 660.00 | 660.00 | 660.00 | 660.00 | 660.00 | 660.00 | |
| Dimensioni (A × L × P) | mm | 30×950×950 | 30×950×950 | 30×950×950 | 30×950×950 | 30×950×950 | 30×950×950 | 30×950×950 | |
| Peso | kg | 20.00 | 20.00 | 24.00 | 24.00 | 24.00 | 24.00 | 24.00 | |
| Griglia | Codice | RBC-U31PG(W)-E2 | RBC-U31PG(W)-E2 | RBC-U31PG(W)-E2 | RBC-U31PG(W)-E2 | RBC-U31PG(W)-E2 | RBC-U31PG(W)-E2 | RBC-U31PG(W)-E2 | |
| Dimensioni della griglia (A x L x P) | mm | 30 x 950 x 950 | 30 x 950 x 950 | 30 x 950 x 950 | 30 x 950 x 950 | 30 x 950 x 950 | 30 x 950 x 950 | 30 x 950 x 950 | |
| Peso griglia | kg | 4.20 | 4.20 | 4.20 | 4.20 | 4.20 | 4.20 | 4.20 | |
| UNITA' ESTERNA | RAV-SP564ATP-E | RAV-SP804ATP-E | RAV-SP1104AT-E | RAV-SP1104AT8-E | RAV-SP1404AT-E | RAV-SP1404AT8-E | RAV-SP1604AT8-E | ||
| Portata Aria (a) (C-H) | m³/h | 2400.00 | 3000.00 | 6060.00 | 6060.00 | 6180.00 | 6180.00 | 6180.00 | |
| Livello di pressione sonora (C-H) | dB(A) | 47-48 | 48-49 | 49-50 | 49-50 | 51-52 | 51-52 | 51-53 | |
| Livello di potenza sonora (C-H) | dB(A) | 63-64 | 64-65 | 66-67 | 66-67 | 68-69 | 68-69 | 68-70 | |
| Intervallo di funzionamento (C) | °C | -15~43 | -15~43 | -15~43 | -15~46 | -15~43 | -15~46 | -15~46 | |
| Intervallo di funzionamento (H) | °C | -20~15 | -20~15 | -20~15 | -20~15 | -20~15 | -20~15 | -20~15 | |
| Dimensioni (A × L × P) | mm | 550 x 780 x 290 | 890 x 900 x 320 | 1340 × 900 × 320 | 1340 x 900 x 320 | 1340 × 900 × 320 | 1340 x 900 x 320 | 1340 x 900 x 320 | |
| Peso | kg | 44 | 63 | 93 | 95 | 93 | 95 | 95 | |
| Compressore | DC Twin Rotary | DC Twin Rotary | DC Twin Rotary | DC Twin Rotary | DC Twin Rotary | DC Twin Rotary | DC Twin Rotary | ||
| Accoppiamento a cartella Gas | 1/2" | 5/8" | 5/8" | 5/8" | 5/8" | 5/8" | 5/8" | ||
| Accoppiamento a cartella Liquido | 1/4" | 3/8" | 3/8" | 3/8" | 3/8" | 3/8" | 3/8" | ||
| Lunghezza delle tubazioni (min-max) | m | 5-20 | 5-30 | 3-30 | 3-30 | 3-30 | 3-30 | 3-30 | |
| Dislivello massimo | m | 30 | 30 | 30 | 30 | 30 | 30 | 30 | |
| Lunghezza delle tubazioni senza carica aggiuntiva | m | 20 | 30 | 30 | 30 | 30 | 30 | 30 | |
| Alimentazione | V-ph-Hz | 220/240-1-50 | 220/240-1-50 | 220/240-1-50 | 380/415-3N-50 | 220/240-1-50 | 380/415-3N-50 | 380/415-3N-50 | |
| Corrente massima | A | 15.00 | 20.80 | 22.80 | 14.70 | 22.80 | 14.70 | 14.70 | |
| The specification may be subject to change without notice for purpose of improvement. | |||||||||